0034.1523.PT
Manufacturer
Model
0034.1523.PT
Category
The SCHURTER 0034.1523.PT is a 5A/250V AC glass tube fuse with 50A interrupt capability, designed for overcurrent protection in low-voltage circuits. It operates reliably between -55°C and +125°C, offering compact D5.4xL22.5mm dimensions and ROHS compliance. Basic applications include general circuit protection and power distribution, while extended use extends to automotive and industrial safety systems. Critical parameters include interrupt rating, current/voltage limits, and thermal tolerance. Engineers should prioritize proper soldering techniques, thermal management, and compatibility checks. Strengths lie in high interrupt performance and compliance, but limitations include stock availability and DC incompatibility.
Reference Pricing
Reference Stock
Specifications
Break Time | 4.0xInmin. |
Color | Not specified |
Dimensions | Not specified |
Fusing Characteristic | 2) |
Operating Temperature Range | -55°C to 125°℃ |
Package Type | DIP,D5.4xL22.5mm |
Rated Current | 10A |
Rated Voltage | 250VAC |
Function And Role
Core Function
Overcurrent protection in low-voltage circuits
Key Characteristics
- 50A interrupt rating
- 5A current rating
- 250V AC voltage rating
- Glass Tube Fuse type
- -55°C to +125°C operating temperature range
Application Domains
Basic Scenarios
- General circuit protection in 250V AC systems
- Low-voltage power distribution
Extended Scenarios
- Automotive electrical systems
- Industrial equipment safety mechanisms
- Consumer electronics power protection
Precautions
Soldering | Use low-temperature solder and avoid prolonged heat exposure |
Current Limit | Max continuous current: 5A |
Voltage Limit | Max AC voltage: 250V |
Thermal Management | Thermal derating required above +125°C |
Storage | Store in dry, cool environments below 30°C |
Risk Warnings |
|
Alternative Model Params
- Interrupt rating (50A±5%)
- Current rating (5A±10%)
- Voltage rating (250V AC±10%)
- Operating temperature range (-55°C to +125°C)
Design Recommendations
Layout | Ensure 10mm minimum spacing from adjacent components |
Thermal | Implement heat sinking for continuous operation above 100°C |
Compatibility | Verify PCB pad dimensions (D5.4xL22.5mm) match |
Testing | Test under 1.5x rated current for 30 minutes pre-deployment |
Market Positioning
Strengths |
|