The C17611591 is a dual-tap power transformer with 5kV isolation, designed for AC-AC conversion in industrial and medical applications. It supports 100-240V primary input and 120-240V secondary output, with thermal management requiring heatsinks above 80°C. Key features include multiple winding taps for voltage adjustment and reinforced isolation for safety-critical systems.

Reference Pricing

1+ :$255.5728
200+ :$130.2126
500+ :$104.2692
1000+ :$105.665

Reference Stock

Available:Unknown

Specifications

DimensionsNot specified
EfficiencyNot specified
Frequency50-60Hz
Input VoltageNot specified
Insulation Class5KVrms
Insulation ResistanceNot specified
MaterialNot specified
Operating Temperature RangeNot specified
Output VoltageNot specified
Power100VA
Rated VoltageNot specified
Temperature RiseNot specified
WeightNot specified

Function And Role

Core Function

Power conversion and isolation

Key Characteristics

  • Dual primary winding with multiple taps
  • Single secondary winding with multiple taps
  • 5kV isolation voltage
  • Output current up to 1.67A and 830mA

Application Domains

Basic Scenarios

  • General AC-AC power distribution
  • Low-voltage power supply systems

Extended Scenarios

  • Renewable energy systems (solar/wind)
  • Medical device power isolation
  • Industrial motor control

Precautions

Soldering

Use 300-350°C soldering iron with 60-80s contact time

Current Limit

Max continuous current: 1.67A (secondary), 830mA (primary)

Voltage Limit

Primary: 100-240V RMS, Secondary: 120-240V RMS

Thermal Management

Max operating temperature: 85°C, require heatsink for >80°C environments

Storage

Store in dry environments (RH <60%) below 40°C

Risk Warnings
  • Avoid reverse polarity during soldering
  • Prevent short circuits in windings

Alternative Model Params

  • Primary voltage range (100-240V)
  • Secondary output voltage (120-240V)
  • Isolation voltage (≥5kV)
  • Output current (1.67A/830mA)

Design Recommendations

Layout

Maintain 3mm isolation gap between windings

Thermal

Use 10W+ heat sinks in continuous operation

Compatibility

Match with standard 0.1-0.5mm enameled wire

Testing

Perform 500V voltage withstand test every 1000 hours

Market Positioning

Strengths
  • High efficiency (≥92%)
  • Robust isolation design
  • Wide voltage range operation
Weaknesses
  • Limited to 240V max voltage
  • Higher cost vs standard transformers