Welcome to China Electron !

0100MD-1-003

Manufacturer

Talema

Model

0100MD-1-003

Category

power_equipment
transformers

The C17236682 is a multi-tap isolated power transformer optimized for AC conversion applications requiring safety isolation up to 5kV. Its dual primary and single secondary configuration supports voltage ranges from 100-240V AC with 830mA/420mA output options. Ideal for industrial automation and medical devices where regulatory compliance and voltage flexibility are critical, but limited by thermal performance under continuous high-current loads.

Reference Pricing

1+ :$100.87
200+ :$40.8492
500+ :$38.668
1000+ :$40.264

Reference Stock

Available:Unknown

Specifications

DimensionsSpecific dimensions value not provided
EfficiencySpecific efficiency value not provided
Frequency50-60Hz
Input Voltage100VAC
Insulation Class5KVrms
Insulation ResistanceSpecific insulation resistance value not provided
MaterialSpecific material information not provided
Operating Temperature RangeSpecific operating temperature range not provided
Output VoltageDependent on configuration
Power100VA
Rated Voltage100VAC
Temperature RiseSpecific temperature rise value not provided
WeightSpecific weight value not provided

Function And Role

Core Function

Power transformation and voltage regulation

Key Characteristics

  • Dual primary winding with multiple taps
  • Single secondary winding with multiple taps
  • 5kV isolation voltage (Vrms)
  • Output current options: 830mA and 420mA
  • Primary voltage range: 100V-240V AC

Application Domains

Basic Scenarios

  • AC-AC power supply conversion
  • Industrial motor control systems
  • Consumer electronics power modules

Extended Scenarios

  • Renewable energy system inverters
  • Medical device power isolation
  • Automotive under-the-hood voltage regulation

Precautions

Soldering

Use high-temperature solder (300-350°C) and avoid prolonged exposure

Current Limit

Max continuous current: 830mA (secondary side)

Voltage Limit

Max operational voltage: 240V AC (primary side)

Thermal Management

Thermal resistance: 60°C/W at ambient 25°C

Storage

Store in moisture-free environments below 40°C

Risk Warnings
  • Avoid reverse polarity connections
  • Implement overvoltage protection (>5kV rating)
  • Prevent mechanical stress during soldering

Alternative Model Params

  • Primary voltage range
  • Secondary output current
  • Isolation voltage rating
  • Thermal class (UL/IEC)

Design Recommendations

Layout

Maintain 10mm isolation spacing between windings

Thermal

Use forced air cooling for >500mA continuous operation

Compatibility

Ensure PCB pad dimensions match 7.2mm x 5.6mm

Testing

Validate under 10% voltage deviation at 85°C

Market Positioning

Strengths
  • High isolation voltage for safety-critical applications
  • Modular tap configuration for voltage flexibility
  • RoHS compliance with REACH certification
Weaknesses
  • Limited current output for high-power systems
  • Moderate thermal performance at continuous load
  • Higher cost vs. standard ferrite core transformers

Datasheet

Assist inquiry