0100MD-1-003
Manufacturer
Model
0100MD-1-003
Category
The C17236682 is a multi-tap isolated power transformer optimized for AC conversion applications requiring safety isolation up to 5kV. Its dual primary and single secondary configuration supports voltage ranges from 100-240V AC with 830mA/420mA output options. Ideal for industrial automation and medical devices where regulatory compliance and voltage flexibility are critical, but limited by thermal performance under continuous high-current loads.
Reference Pricing
Reference Stock
Specifications
Dimensions | Specific dimensions value not provided |
Efficiency | Specific efficiency value not provided |
Frequency | 50-60Hz |
Input Voltage | 100VAC |
Insulation Class | 5KVrms |
Insulation Resistance | Specific insulation resistance value not provided |
Material | Specific material information not provided |
Operating Temperature Range | Specific operating temperature range not provided |
Output Voltage | Dependent on configuration |
Power | 100VA |
Rated Voltage | 100VAC |
Temperature Rise | Specific temperature rise value not provided |
Weight | Specific weight value not provided |
Function And Role
Core Function
Power transformation and voltage regulation
Key Characteristics
- Dual primary winding with multiple taps
- Single secondary winding with multiple taps
- 5kV isolation voltage (Vrms)
- Output current options: 830mA and 420mA
- Primary voltage range: 100V-240V AC
Application Domains
Basic Scenarios
- AC-AC power supply conversion
- Industrial motor control systems
- Consumer electronics power modules
Extended Scenarios
- Renewable energy system inverters
- Medical device power isolation
- Automotive under-the-hood voltage regulation
Precautions
Soldering | Use high-temperature solder (300-350°C) and avoid prolonged exposure |
Current Limit | Max continuous current: 830mA (secondary side) |
Voltage Limit | Max operational voltage: 240V AC (primary side) |
Thermal Management | Thermal resistance: 60°C/W at ambient 25°C |
Storage | Store in moisture-free environments below 40°C |
Risk Warnings |
|
Alternative Model Params
- Primary voltage range
- Secondary output current
- Isolation voltage rating
- Thermal class (UL/IEC)
Design Recommendations
Layout | Maintain 10mm isolation spacing between windings |
Thermal | Use forced air cooling for >500mA continuous operation |
Compatibility | Ensure PCB pad dimensions match 7.2mm x 5.6mm |
Testing | Validate under 10% voltage deviation at 85°C |
Market Positioning
Strengths |
|
Weaknesses |
|